Changing network adapter type in VMware Vsphere

 Changing network adapter type in VMWare Vsphere

Tested on VSphere 5.1.




Figure 1


There is no option available in vsphere client to change the current installed network adapter type, You will have to either install a new network adapter or you can change the existing network adapter type through powercli, you can create a script to change adapter type of all the VM in vcenter or on Esxi server, at one shot.




Figure 2


Open powercli from start menu,


Connect to vCenter server (you can connect directly to esxi server as well), by executing below command you will log onto vcenter server (my vcenter IP address is 192.168.33.12, you can use servername or FQDN as well)

Figure 3


Once the command executed it will pop up and ask for credentials, Make sure you have appropriate permissions on vcenter.



Figure 4


Now you are logged into vcenter successfully, you will see something like below, how you are connected to vcentre server.



Figure 5


Find The VM for which you want to change the adapter type. Fire command "get-vm", it query the list of VMs available on vcenter. Here I want to change network adapter type for winxp001.vcloud.lab.

Figure 6


Next command to get details about network adapter type of VM winxp001.vcloud.lab. Here I used get-networkadapter in pipe line to query network adapter details.


Get-VM winxp001.vcloud.lab | get-networkadapter

Figure 7


Now it's time to change network adapter type, below is the link for description about all the available network adapter types.


http://pubs.vmware.com/vsphere-50/index.jsp?topic=%2Fcom.vmware.vsphere.vm_admin.doc _50%2FGUID-AF9E24A8-2CFA-447B-AC83-35D563119667.html


fire below command, next it will ask for confirmation if you want to continue with changing the adapter type


Code:
get-vm winxp001.vcloud.lab | Get-NetworkAdapter | set-networkadapter -type vmxnet3
Note: If you have more than one VMNIC the command will ask if you want to apply to each NIC one by one with YES or NO.
Or to YES TO ALL in first ask to change all NICs type in one shot.



Figure 8


If you check on network adapter under VM settings, you will see the changes.

Figure 9


Here in the above example I changed adapter type for only one VM but if you have multiple servers servers and want to automate changing adapter type using script. Below is the simple script.


Connect to vcenter or esxi host, Create a list of VMs in text file and keep it on reachable location, here I have created list, named the file vmlist.txt and kept it on C drive.


$VMlist = Get-content c:\VMlist.txt

Get-VM $VMlist | Get-NetworkAdapter | set-networkadapter -type vmxnet3 -confirm:$false


Now get-vm will query VM properties and settings from $vmlist which contains text file data, by piping information into get-networkadapter I am querying network adapter properties and settings, and again I am piping the information into "set-networkadapter -type vmxnet3" to change type. In the last option "-confirm:$false" is used to skip confirmation (figure 8) and continue with action.

Comments

Popular posts from this blog

Integration with vCloud Director failing after NSXT upgrade to 4.1.2.0 certificate expired

  Issue Clarification: after upgrade from 3.1.3 to 4.1.2.0 observed certificate to be expired related to various internal services.   Issue Verification: after Upgrade from 3.1.3 to 4.1.2.0 observed certificate to be expired related to various internal services.   Root Cause Identification: >>we confirmed the issue to be related to the below KB NSX alarms indicating certificates have expired or are expiring (94898)   Root Cause Justification:   There are two main factors that can contribute to this behaviour: NSX Managers have many certificates for internal services. In version NSX 3.2.1, Cluster Boot Manager (CBM) service certificates were incorrectly given a validity period of 825 days instead of 100 years. This was corrected to 100 years in NSX 3.2.3. However any environment originally installed on NSX 3.2.1 will have the internal CBM Corfu certs expire after 825 regardless of upgrade to the fixed version or not. On NSX-T 3.2.x interna...

Calculate how much data can be transferred in 24 hours based on link speed in data center

  In case you are planning for migration via DIA or IPVPN link and as example you have 200Mb stable speed so you could calculate using the below formula. (( 200Mb /8)x60x60x24) /1024/1024 = 2TB /per day In case you have different speed you could replace the 200Mb by any rate to calculate as example below. (( 5 00Mb /8)x60x60x24) /1024/1024 =  5.15TB  /per day So approximate each 100Mb would allow around 1TB per day.

Device expanded/shrank messages are reported in the VMkernel log for VMFS-5

    Symptoms A VMFS-5 datastore is no longer visible in vSphere 5 datastores view. A VMFS-5 datastore is no longer mounted in the vSphere 5 datastores view. In the  /var/log/vmkernel.log  file, you see an entry similar to: .. cpu1:44722)WARNING: LVM: 2884: [naa.6006048c7bc7febbf4db26ae0c3263cb:1] Device shrank (actual size 18424453 blocks, stored size 18424507 blocks) A VMFS-5 datastore is mounted in the vSphere 5 datastores view, but in the  /var/log/vmkernel.log  file you see an entry similar to: .. cpu0:44828)LVM: 2891: [naa.6006048c7bc7febbf4db26ae0c3263cb:1] Device expanded (actual size 18424506 blocks, stored size 18422953 blocks)   Purpose This article provides steps to correct the VMFS-5 partition table entry using  partedUtil . For more information see  Using the partedUtil command line utility on ESX and ESXi (1036609) .   Cause The device size discrepancy is caused by an incorrect ending sector for the VMFS-5 partition on the ...