Skip to main content

Fix for OWA always uses Light Mode for some users

 

This article explains the difference between OWA Light Mode and Premium Mode and why some users may only see the Light Mode client, even though they haven't selected it at logon.



Exchange 2007 Outlook Web Access and Exchange 2010 Outlook Web App offer two different modes for viewing OWA - Premium Mode, with all the bells and whistles that Internet Explorer can muster, and Light Mode, which provides fewer features and is sometimes faster. You would usually use the Light client if you are on a slow connection or using a computer with unusually strict browser security settings.


If you are using a browser other than Internet Explorer 6 or later for OWA 2007, you can only use the Light client. OWA 2010 supports the full Outlook Web App experience (aka Premium Mode) on Internet Explorer 7 and some other browsers on Windows, Mac, and Linux computers. To check out all the supported browsers and operating systems for OWA 2010, click here.


Here's a comparison between the Outlook Web Access 2007 Light and Premium clients:

And here's a comparison between the Outlook Web App 2010 Light and Premiun clients:

Normally, users will default to use the Premium Mode client if they are using IE6 or better for OWA 2007 or IE7 or better for OWA 2010. However, you may hear complaints from some users that they always get the Light Mode client, regardless of whether they selected to use it or not when they logged in. This happens if the user selected to use "the blind and low vision experience" when logging into OWA for the first time.

To disable this mode and allow IE to use the Premium Mode, have the user login to OWA and open Options in the upper right corner. Then select Accessibility and clear the checkbox for Use the blind and low vision experience, as shown below.

Now have the user sign out of OWA and sign back in. They should be using OWA Premium Mode, providing they are using a supported browser.

Comments

Popular posts from this blog

Integration with vCloud Director failing after NSXT upgrade to 4.1.2.0 certificate expired

  Issue Clarification: after upgrade from 3.1.3 to 4.1.2.0 observed certificate to be expired related to various internal services.   Issue Verification: after Upgrade from 3.1.3 to 4.1.2.0 observed certificate to be expired related to various internal services.   Root Cause Identification: >>we confirmed the issue to be related to the below KB NSX alarms indicating certificates have expired or are expiring (94898)   Root Cause Justification:   There are two main factors that can contribute to this behaviour: NSX Managers have many certificates for internal services. In version NSX 3.2.1, Cluster Boot Manager (CBM) service certificates were incorrectly given a validity period of 825 days instead of 100 years. This was corrected to 100 years in NSX 3.2.3. However any environment originally installed on NSX 3.2.1 will have the internal CBM Corfu certs expire after 825 regardless of upgrade to the fixed version or not. On NSX-T 3.2.x interna...

Calculate how much data can be transferred in 24 hours based on link speed in data center

  In case you are planning for migration via DIA or IPVPN link and as example you have 200Mb stable speed so you could calculate using the below formula. (( 200Mb /8)x60x60x24) /1024/1024 = 2TB /per day In case you have different speed you could replace the 200Mb by any rate to calculate as example below. (( 5 00Mb /8)x60x60x24) /1024/1024 =  5.15TB  /per day So approximate each 100Mb would allow around 1TB per day.

Device expanded/shrank messages are reported in the VMkernel log for VMFS-5

    Symptoms A VMFS-5 datastore is no longer visible in vSphere 5 datastores view. A VMFS-5 datastore is no longer mounted in the vSphere 5 datastores view. In the  /var/log/vmkernel.log  file, you see an entry similar to: .. cpu1:44722)WARNING: LVM: 2884: [naa.6006048c7bc7febbf4db26ae0c3263cb:1] Device shrank (actual size 18424453 blocks, stored size 18424507 blocks) A VMFS-5 datastore is mounted in the vSphere 5 datastores view, but in the  /var/log/vmkernel.log  file you see an entry similar to: .. cpu0:44828)LVM: 2891: [naa.6006048c7bc7febbf4db26ae0c3263cb:1] Device expanded (actual size 18424506 blocks, stored size 18422953 blocks)   Purpose This article provides steps to correct the VMFS-5 partition table entry using  partedUtil . For more information see  Using the partedUtil command line utility on ESX and ESXi (1036609) .   Cause The device size discrepancy is caused by an incorrect ending sector for the VMFS-5 partition on the ...